AARICO

transmitter/transducer

Showing These Transducer and Transmitter:

SL17 - Submersible Pressure Transmitter

The Ashcroft® SL17 submersible transmitter combines ruggedness with proven sensor technology for satisfying challenging applications.

Accuracy

±0.25% for ranges > 1.5 psi, ±0.5% for 1.5 psi

output

4-20 mA

Ranges

1.5 to 300 psi

T2 Pressure Transducer

The Ashcroft® T2 pressure transducer provides outstanding integrity concerning high shock, vibration and pressure cycling.

Accuracy

±0.25% of span

output

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

Ranges

30 to 20,000 psig, compound to 300 psig

G2 Pressure Transducer

The Ashcroft® G2 combines performance with value. An versatile product platform, it excels in even the most challenging application.

Accuracy

±1% span: total error band through -20/85°C (-4/185°F), ±1.5% span: through -40/-20°C (-40/-4°F) and 85/125°C (185/257°F)

output

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

Ranges

30 to 20,000 psig, compound to 300 psig

G3 Pressure Transducer

The Ashcroft G3 pressure transducer is a highly accurate, compact, economical and repeatable transducer for gauges and absolute pressure ranges.

Accuracy

±1.5% span: total error band through -20/85°C (-4/185°F), ±2% span: total error band through -40/-20°C (-40/-4°F) and 85/125°C (185/257°F)

output

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

Ranges

vacuum, compound and 5 to 300 psig, 15 to 300 psia

A2 Industrial Pressure Transmitter

The Ashcroft® A2 industrial pressure transmitter is designed to satisfy the requirements of industrial applications.

Accuracy

±0.25, ±0.5, ±1% of span

output

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

Ranges

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig

A4 Intrinsically Safe/Non-Incendive Pressure Transmitter

The Ashcroft® A4 pressure transmitter fulfills a wide spectrum of pressure sensing requirements where Intrinsically Safe or Non-Incendive hazardous location ratings are needed.

Accuracy

±.25, ±0.5, ±1.0% of span

output

4-20mA

Ranges

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig

A2X Explosion/Flame Proof Pressure Transmitter

The Ashcroft® A2X pressure transmitter fulfills a wide spectrum of pressure sensing requirements when explosion and flame-proof hazardous location ratings are needed.

Accuracy

±0.25, ±0.5, ±1.0% of span

output

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

Ranges

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig

K1 Pressure Transducer/Transmitter

The Ashcroft® K1 is a proven and versatile pressure transducer/transmitter. Sensor technology and assembly method eliminates signal instability and drift; making this product virtually unaffected by shock or vibration.

Accuracy

±0.5%, ±1.0% of span

output

4-20mA, 1-5Vdc, 1-6Vdc, 1-11Vdc

Ranges

15 to 20,000 psig, compound to 60 psig

K2 Pressure Transducer with Millivolt Output

The Ashcroft® K2 shares the same platform as the model K1, except offered with a millivolt option.

Accuracy

±0.5%, ±1.0% of span

output

2, 3, 10, 20 mV/V

Ranges

15 to 20,000 psig, compound to 60 psig

KX Flush Mount Pressure Transducer

The Ashcroft® KX pressure transmitter combines benefits of polysilicon thin film performance with the utility of a flush-mounting sensing diaphragm.

Accuracy

±1.0% of span

output

4-20mA, 1-5Vdc, 1-6Vdc

Ranges

100 to 5000 psig

KS Sanitary Transducer/Transmitter

The Ashcroft® KS sanitary pressure transducer/transmitter combines proven polysilicon thin film technology with diaphragm seal expertise.

Accuracy

±1.0% of span

output

4-20mA, 1-5Vdc, 1-6Vdc, 2, 3, 10, 20 mV/V ratiometric

Ranges

30 to 1000 psig, compound to 100 psig

K8 Pressure Sensor

The Ashcroft® K8 is a proven reliable pressure sensor.

Accuracy

±0.5%, ±1.0% of span

output

Varies from 6-18mV/V at span ratiometric

Ranges

45 to 20,000 psig

KM15 OEM Pressure Transducer

The Ashcroft® KM15 pressure transducer is ideal when a durable and economical pressure transducer is needed.

Accuracy

100 psig and above- ±0.5% of span , 75 psig and below - ±1.0% of span

output

1-5Vdc, 1-6Vdc, 0.5 - 4.5Vdc (ratiometric)

Ranges

15 to 7500 psig, compound to 300 psig

GC31 Indicating Pressure Transducer with Switch Outputs

The Ashcroft® GC31 is an ultra compact indicating transducer with analog scaling and switch outputs.

Accuracy

±1.0% of span

output

1-5Vdc

Ranges

Gauge: 50 to 1500 psig, Compound: -15 to 15 psig thru -15 to 300 psig5" - 1/4" NPT 30-1000 PSI 1339A 4.5" - 1/4" NPT 30/1000 PSI Back Connect Only

GC35 Indicating Pressure Transducer with Switch Outputs

The Ashcroft® GC35 is a compact indicating transducer with analog scaling and switch outputs.

Accuracy

±1.0% of span

output

4-20mA

Ranges

Gauge: 50 to 7500 psig, Compound: -15 to 75 psig thru -15 o 300 psig

GC51 Rangeable Indicating Pressure Transmitter

The Ashcroft® GC51 pressure transmitter incorporates field-proven thin film technology, and can be used for monitoring a wide variety of wet or dry media.

Accuracy

±0.25% of span (URL)0

output

4-20mA (2 wire)

Ranges

Gauge: 50 to 7500 psig, Compound: -15 to 15 psi thru -15 to 50 psi

GC55 Wet/Wet Indicating Differential Pressure Transducer with Switch Outputs

The Ashcroft® GC55 is a high-differential pressure transducer incorporating two thin film sensors; unit output signaling may be connected to external controls or data acquisition.

Accuracy

±0.5% of span

output

4-20mA, 1-5Vdc

Ranges

Differential: 75 to 300 psid

GC30 Indicating Differential Pressure Transducer with Switch Outputs

The Ashcroft® GC30 differential pressure transducer uses field-proven thin film sensor technology for monitoring a wide variety of applications.

Accuracy

±1.5% of span

output

1-5Vdc

Ranges

Gauge: 0.25 I.W.C. to 25 I.W.C., Compound ±0.25 I.W.C to ±25 I.W.C.

GC52 Rangeable Wet/Wet Differential Pressure Transmitter

The Ashcroft® GC52 wet/wet differential pressure transmitter where consistent, reliable low DP measurement is essential.

Accuracy

±0.50% of span (URL)

output

4.20mA (2 wire)

Ranges

Bidirectional Inches of Water: ±4 to ±200 I.W.C., Unidirectional Inches of Water: 0 to 4 thru 400 I.W.C

CXLdp Differential Pressure Transmitter

The Ashcroft® CXLdp differential pressure transmitter uses the patented Si-Glas™ variable capacitance sensor, providing excellent sensitivity and long term stability.

Accuracy

±0.25%, ±0.4% or ±0.8% of span

output

4.20mA, 0-5Vdc, 0-10Vdc, (24Vac/Vdc)

Ranges

Unidirectional: 0.10 to 0/25 I.W.C.: Bidirectional: ±0.10 to ±15 I.W.C.

GL42 Indicating Differential Pressure Transmitter

The Ashcroft® GL42 low differential indicating pressure transmitter is used for measurement and control of extremely low pressures and flow.

Accuracy

±0.50% or ±1.00 FS (URL)

output

4-20mA (2 wire)

Ranges

Bidirectional: ±0.05 to ±15.0 I.W.C, Unidirectional: 0.10 to 25 I.W.C

DXLdp Differential Pressure Transmitter

The Ashcroft® DXLdp differential transmitter uses patented Si-Glass™ technology, assuring precise measurement and control at extremely low dP pressures.

Accuracy

0.25%, 0.50%, or 1.00% of span

output

4-20mA, 1-5Vdc, 1-6Vdc, 0-5Vdc, 0-10Vdc

Ranges

Unidirectional: 0.10 to 100 I.W.C, Bidirectional: ±0.05 to ±100 I.W.C.

RXLdp Differential Pressure Transmitter

The Ashcroft® RXLdp differential transmitter utilizes patented Si-Glass™ technology, assuring precise measurement and control at extremely low differential pressures.

Accuracy

1.00% of span

output

4-20mA, (12-36Vdc), 1-5Vdc, 1-6Vdc, 0-5Vdc, 0-10Vdc

Ranges

Bidirectional: ±0.05 to ±50 I.W.C., Unidirectional: 0.10 to 50 I.W.C.

XLdp Differential Pressure Transmitter

The Ashcroft® XLdp differential transmitter uses patented Si-Glass™ technology which provides precise measurement and control at extremely low dP pressures.

Accuracy

0.25% or 0.50% of span

output

4-20mA, (12-36Vdc), 1-5Vdc, 1-6Vdc

Ranges

Bidirectional: ±0.05 to ±50 I.W.C., Unidirectional: 0.10 to 100 I.W.C.

IXLdp Differential Pressure Transmitter

The Ashcroft® IXLdp industrial differential transmitter is used for measurement and control of extremely low pressures and flow.

Accuracy

0.25% or 0.50% of span

output

4-20mA, 1-5Vdc, 1-6Vdc, ±5Vdc, ±2.5Vdc

Ranges

Bidirectional: ±0.05 to ±100 I.W.C., Unidirectional: 0.10 to 200 I.W.C.

AXLdp Low Differential Pressure Transducer

The AXLdp is designed for OEM systems that require an ultra-low differential pressure sensor that can be PC Board mounted.

Accuracy

±1% or ±2% span

output

Ratiometric 0.5 to 4.5 V with a 5Vdc supply

Ranges

Bidirectional Inches of Water: ±0.10 to ±10 I.W.C. Unidirectional Inches of Water: 0.20 to 4 thru 20 I.W.C